2.2.1.6. Enable FPGA Cross Trigger Interface
The cross trigger interface (CTI) allows trigger sources and sinks in FPGA logic to interface with the embedded cross trigger (ECT).
For more information, refer to the CoreSight Debug and Trace chapter in the Hard Processor System Technical Reference Manual: Agilex™ 5 SoCs.
If this interface must be connected to a Signal Tap instance in the FPGA fabric, then it must be left disabled in Platform Designer. Turning on the Enable CTI interface option enables the fpga_cti conduit, which is comprised of the following signals:
Signal Name | Interface Type |
---|---|
fpga_cti_trig_in[7…0] |
Conduit |
fpga_cti_trig_out[7…0] |
Conduit |
fpga_cti_trig_in_ack[7…0] |
Conduit |
fpga_cti_trig_out_ack[7…0] |
Conduit |