Visible to Intel only — GUID: mwh1410383457646
Ixiasoft
1. Answers to Top FAQs
2. Intel FPGA Simulation Basics
3. Siemens EDA QuestaSim* Simulator Support
4. Synopsys VCS* and VCS MX Support
5. Aldec Active-HDL and Riviera-PRO Support
6. Cadence Xcelium* Parallel Simulator Support
7. Intel® Quartus® Prime Pro Edition User Guide Third-party Simulation Archive
A. Intel® Quartus® Prime Pro Edition User Guides
Visible to Intel only — GUID: mwh1410383457646
Ixiasoft
3.2.2. Viewing Simulation Messages
QuestaSim* simulator error and warning messages are tagged with a vsim or vcom code. To determine the cause and resolution for a vsim or vcom error or warning, use the verror command.
For example, QuestaSim* may return the following error:
# ** Error: C:/altera_trn/DUALPORT_TRY/simulation/modelsim/DUALPORT_TRY.vho(31): (vcom-1136) Unknown identifier "stratixiv"
In this case, type the following command:
verror 1136
The following description appears:# vcom Message # 1136: # The specified name was referenced but was not found. This indicates # that either the name specified does not exist or is not visible at # this point in the code.