AN 741: Remote System Upgrade for MAX 10 FPGA Devices over UART with the Nios II Processor
ID
683661
Date
2/21/2017
Public
Visible to Intel only — GUID: sss1430812630147
Ixiasoft
1.6.2.2. Triggering Reconfiguration Remotely
After you select trigger reconfiguration operation in the host Remote Terminal, the Nios II software application will do the following:
- Receive the command from standard input.
- Start the reconfiguration with the following two write operations:
- Write 0x03 to the offset address of 0x01 in the Dual Configuration IP core. This operation overwrites the physical CONFIG_SEL pin and sets Image 1 as the next boot configuration image.
- Write 0x01 to the offset address of 0x00 in the Dual Configuration IP core. This operation triggers reconfiguration to application image in CFM1 and CFM2