2.2.1. PLL Features
2.2.2. PLL Usage
2.2.3. PLL Architecture
2.2.4. PLL Control Signals
2.2.5. Clock Feedback Modes
2.2.6. Clock Multiplication and Division
2.2.7. Programmable Phase Shift
2.2.8. Programmable Duty Cycle
2.2.9. PLL Cascading
2.2.10. Clock Switchover
2.2.11. PLL Reconfiguration and Dynamic Phase Shift
2.2.12. PLL Calibration
4.3.4.1. Design Example 1: .mif Streaming Reconfiguration Using IOPLL Reconfig IP Core
4.3.4.2. Design Example 2: Advanced Mode Reconfiguration Using IOPLL Reconfig IP Core
4.3.4.3. Design Example 3: Clock Gating Reconfiguration Using IOPLL Reconfig IP Core
4.3.4.4. Design Example 4: Dynamic Phase Shift Using IOPLL Reconfig IP Core
4.3.3. IOPLL Reconfig IP Core Reconfiguration Modes
The IOPLL Reconfig IP core has four functional reconfiguration modes. The reconfiguration operation mode is based on the setting in the mgmt_address[9:8] bit.
Reconfiguration Mode | mgmt_address[9:8] |
---|---|
.mif streaming reconfiguration | 2'b 00 |
Advanced mode reconfiguration | 2'b 01 |
Clock gating reconfiguration | 2'b 10 |
Dynamic phase shift reconfiguration | 2'b 11 |
After performing dynamic reconfiguration on the I/O PLL that changes the M counter, N counter, bandwidth setting, or charge pump current, the I/O PLL must be recalibrated. For .mif streaming reconfiguration, the recalibration is done automatically. For advanced mode reconfiguration, you must manually trigger the recalibration of the I/O PLL. Recalibration is not needed for clock gating and dynamic phase shift reconfiguration.