Visible to Intel only — GUID: fmk1547841996611
Ixiasoft
1. Overview
2. Use Cases
3. Quad SPI Flash Layout
4. Intel® Quartus® Prime Software and Tool Support
5. Software Support
6. Flash Corruption - Detection and Recovery
7. Remote System Update Example
8. Version Compatibility Considerations
9. Intel® Stratix® 10 Hard Processor System Remote System Update User Guide Archives
10. Document Revision History for the Intel® Stratix® 10 Hard Processor System Remote System Update User Guide
A. Configuration Flow Diagrams
B. RSU Status and Error Codes
C. U-Boot RSU Reference Information
D. LIBRSU Reference Information
E. Combined Application Images
2.1. Manufacturing
2.2. Application Image Boot
2.3. Factory Image Boot
2.4. Modifying the List of Application Images
2.5. Querying RSU Status
2.6. Loading a Specific Image
2.7. Protected Access to Flash
2.8. Remote System Update Watchdog
2.9. RSU Notify
2.10. Updating the Factory Image
2.11. Updating the Decision Firmware
2.12. Retrying when Configuration Fails
2.13. Querying the Decision Firmware Version
C.6.1. rsu_init
C.6.2. rsu_exit
C.6.3. rsu_slot_count
C.6.4. rsu_slot_by_name
C.6.5. rsu_slot_get_info
C.6.6. rsu_slot_size
C.6.7. rsu_slot_priority
C.6.8. rsu_slot_erase
C.6.9. rsu_slot_program_buf
C.6.10. rsu_slot_program_factory_update_buf
C.6.11. rsu_slot_program_buf_raw
C.6.12. rsu_slot_verify_buf
C.6.13. rsu_slot_verify_buf_raw
C.6.14. rsu_slot_enable
C.6.15. rsu_slot_disable
C.6.16. rsu_slot_load
C.6.17. rsu_slot_load_factory
C.6.18. rsu_slot_rename
C.6.19. rsu_slot_delete
C.6.20. rsu_slot_create
C.6.21. rsu_status_log
C.6.22. rsu_notify
C.6.23. rsu_clear_error_status
C.6.24. rsu_reset_retry_counter
C.6.25. rsu_dcmf_version
C.6.26. rsu_max_retry
C.6.27. rsu_dcmf_status
C.6.28. rsu_create_empty_cpb
C.6.29. rsu_restore_cpb
C.6.30. rsu_save_cpb
C.6.31. rsu_restore_spt
C.6.32. rsu_save_spt
C.6.33. rsu_running_factory
C.7.1. dtb
C.7.2. list
C.7.3. slot_by_name
C.7.4. slot_count
C.7.5. slot_disable
C.7.6. slot_enable
C.7.7. slot_erase
C.7.8. slot_get_info
C.7.9. slot_load
C.7.10. slot_load_factory
C.7.11. slot_priority
C.7.12. slot_program_buf
C.7.13. slot_program_buf_raw
C.7.14. slot_program_factory_update_buf
C.7.15. slot_rename
C.7.16. slot_delete
C.7.17. slot_create
C.7.18. slot_size
C.7.19. slot_verify_buf
C.7.20. slot_verify_buf_raw
C.7.21. status_log
C.7.22. update
C.7.23. notify
C.7.24. clear_error_status
C.7.25. reset_retry_counter
C.7.26. display_dcmf_version
C.7.27. display_dcmf_status
C.7.28. display_max_retry
C.7.29. restore_spt
C.7.30. save_spt
C.7.31. create_empty_cpb
C.7.32. restore_cpb
C.7.33. save_cpb
C.7.34. check_running_factory
D.6.1. librsu_init
D.6.2. librsu_exit
D.6.3. rsu_slot_count
D.6.4. rsu_slot_by_name
D.6.5. rsu_slot_get_info
D.6.6. rsu_slot_size
D.6.7. rsu_slot_priority
D.6.8. rsu_slot_erase
D.6.9. rsu_slot_program_buf
D.6.10. rsu_slot_program_factory_update_buf
D.6.11. rsu_slot_program_file
D.6.12. rsu_slot_program_factory_update_file
D.6.13. rsu_slot_program_buf_raw
D.6.14. rsu_slot_program_file_raw
D.6.15. rsu_slot_verify_buf
D.6.16. rsu_slot_verify_file
D.6.17. rsu_slot_verify_buf_raw
D.6.18. rsu_slot_verify_file_raw
D.6.19. rsu_slot_program_callback
D.6.20. rsu_slot_program_callback_raw
D.6.21. rsu_slot_verify_callback
D.6.22. rsu_slot_verify_callback_raw
D.6.23. rsu_slot_copy_to_file
D.6.24. rsu_slot_enable
D.6.25. rsu_slot_disable
D.6.26. rsu_slot_load_after_reboot
D.6.27. rsu_slot_load_factory_after_reboot
D.6.28. rsu_slot_rename
D.6.29. rsu_slot_delete
D.6.30. rsu_slot_create
D.6.31. rsu_status_log
D.6.32. rsu_notify
D.6.33. rsu_clear_error_status
D.6.34. rsu_reset_retry_counter
D.6.35. rsu_dcmf_version
D.6.36. rsu_max_retry
D.6.37. rsu_dcmf_status
D.6.38. rsu_save_spt
D.6.39. rsu_restore_spt
D.6.40. rsu_save_cpb
D.6.41. rsu_create_empty_cpb
D.6.42. rsu_restore_cpb
D.6.43. rsu_running_factory
D.7.1. count
D.7.2. list
D.7.3. size
D.7.4. priority
D.7.5. enable
D.7.6. disable
D.7.7. request
D.7.8. request-factory
D.7.9. erase
D.7.10. add
D.7.11. add-factory-update
D.7.12. add-raw
D.7.13. verify
D.7.14. verify-raw
D.7.15. copy
D.7.16. log
D.7.17. notify
D.7.18. clear-error-status
D.7.19. reset-retry-counter
D.7.20. display-dcmf-version
D.7.21. display-dcmf-status
D.7.22. display-max-retry
D.7.23. create-slot
D.7.24. delete-slot
D.7.25. restore-spt
D.7.26. save-spt
D.7.27. create-empty-cpb
D.7.28. restore-cpb
D.7.29. save-cpb
D.7.30. check-running-factory
D.7.31. help
Visible to Intel only — GUID: fmk1547841996611
Ixiasoft
D.6.31. rsu_status_log
Prototype | int rsu_status_log(struct rsu_status_info *info); |
Description | Copy the SDM status log to info struct. |
Parameters | info: pointer to info struct to fill in |
Return Value | 0 on success, or error code |