1. Agilex™ 7 FPGA M-Series Clocking and PLL Overview
2. M-Series Clocking and PLL Architecture and Features
3. M-Series Clocking and PLL Design Considerations
4. Clock Control IP Core
5. IOPLL IP Core
6. I/O PLL Reconfiguration
7. Agilex™ 7 Clocking and PLL User Guide: M-Series Archives
8. Document Revision History for the Agilex™ 7 Clocking and PLL User Guide: M-Series
2.2.1. PLL Features
2.2.2. PLL Usage
2.2.3. PLL Locations
2.2.4. PLL Architecture
2.2.5. PLL Control Signals
2.2.6. PLL Feedback Modes
2.2.7. Clock Multiplication and Division
2.2.8. Programmable Phase Shift
2.2.9. Programmable Duty Cycle
2.2.10. PLL Cascading
2.2.11. PLL Input Clock Switchover
2.2.12. PLL Reconfiguration and Dynamic Phase Shift
2.2.13. PLL Calibration
6.1.1. Release Information for EMIF Calibration IP
6.1.2. Setting Up the IOPLL IP
6.1.3. Setting Up the EMIF Calibration IP
6.1.4. Connectivity Between IOPLL FPGA IP and EMIF Calibration IP
6.1.5. Axilite Interface Ports in the EMIF Calibration IP
6.1.6. Reconfiguration Guideline for I/O PLLs
6.1.7. Design Example for I/O PLL Reconfiguration
3.6. IP Core Constraints
To implement the IOPLL IP core, you must adhere to the following constraints:
- Any SDC design constraints referring to the I/O PLL clocks must be listed after the SDC constraints for the IOPLL IP core.
- Altera recommends reading the SDC for all I/O PLLs first in a design. You can do this by listing the IP before others in the .qsf file.