6.1.6.4. Recalibration of I/O PLL
- Set the address bus value according to the table below:
Address Bus Value for HSIO I/O PLL Reconfiguration Value s0_axi4lite_awaddr [7:0] 0x88 s0_axi4lite_awaddr [20:13] I/O PLL Base Address s0_axi4lite_awaddr [23:21] 3’b101 - Assert bit [11] of the s0_axi4lite_wdata data bus high to initiate recalibration. Asserted lock signal indicates that the recalibration is complete.