3.4.4.1. External Puncturing
Both parallel and hybrid architectures support external puncturing.
All punctured codes are based on a mother code of rate 1/2. For external depuncturing you must depuncture the received data stream external to the decoder and input the data into the decoder n symbols at a time.
| Punctured Rate | Puncturing Scheme | |||||||
|---|---|---|---|---|---|---|---|---|
| Bit | Multiplier | |||||||
| 2/3 | CA | 1 | 0 | |||||
| CB | 1 | 1 | ||||||
| 3/4 | CA | 1 | 0 | 1 | ||||
| CB | 1 | 1 | 0 | |||||
| 4/5 | CA | 1 | 0 | 0 | 0 | |||
| CB | 1 | 1 | 1 | 1 | ||||
| 5/6 | CA | 1 | 0 | 1 | 0 | 1 | ||
| CB | 1 | 1 | 0 | 1 | 0 | |||
| 6/7 | CA | 1 | 0 | 0 | 1 | 0 | 1 | |
| CB | 1 | 1 | 1 | 0 | 1 | 0 | ||
| 7/8 | CA | 1 | 1 | 1 | 1 | 0 | 1 | 0 |
| CB | 1 | 0 | 0 | 0 | 1 | 0 | 1 | |