Visible to Intel only — GUID: vgo1461074076223
Ixiasoft
2.8.1. Link Consistency
2.8.2. Data Rate
2.8.3. Reference Clock Frequency
2.8.4. Port Type
2.8.5. Self Synchronized Link Up
2.8.6. Scramble
2.8.7. Broadcast Mode
2.8.8. Lane Polarity and Order Reversal
2.8.9. Data Type
2.8.10. Packet Type
2.8.11. Flow Control Operation
2.8.12. Transmit/Receive FIFO Buffers
2.8.13. Data Integrity Protection: CRC
2.8.14. Transceiver Configuration
2.8.15. Error Handling
2.8.16. Optimizing the Implementation
Visible to Intel only — GUID: vgo1461074076223
Ixiasoft
2.8.14.1. Voltage Output Differential (VOD) Control Settings
The Stratix IV transceivers allow you to set the VOD to handle different length, backplane, and receiver requirements.
A range from 200 to 1,200 mV is supported for Stratix IV devices. Arria II GX devices have a fixed value, which cannot be changed. The range is decoded using the GUI integer value and the on-chip transmitter programmable termination values.
VOD Value (Per Lane) | 100 Ω (mV) Stratix IV |
---|---|
0 | 200 |
1 | 400 |
2 | 600 |
3 | 700 |
4 | 800 |
5 | 900 |
6 | 1,000 |
7 | 1,200 |