2.1.1.1. Occasional equalization timeout or PCIe link training failure to achieve expected link speed during speed change, hot reset, and link disable
2.1.1.2. Both ERR_COR and ERR_FATAL messages are sent when TLP with ECRC error is received
2.1.1.3. Multiple error messages are generated by the multifunction device when a non-function-specific error occurs
2.1.1.4. Transmission of all Ethernet frames is suspended upon reception of PAUSE frame request from External link partner
2.1.1.5. Reduced Reference Clock Frequency Options for Certain Output Frequencies in GTS System PLL Clocks IP
2.1.1.6. DisplayPort IP Performance Instability Issue
2.1.1.7. IEEE 1588v2 PTP Accuracy Issue for GTS Ethernet Hard IP for 10GE Rate Designs
2.1.3.1. The USB 3.1 controller has a spillover condition during IN transfers for bulk endpoint which causes a DBE issue for the ISOC-IN Endpoint
2.1.3.2. USB 3.1 Controller Device Drops eSS ISOC Data if the ITP Delta Value is Greater than 63 units
Description
Workaround
2.1.3.3. The USB 3.1 controller has a possible glitch on the clock output during U3 to U0 power state transition
2.1.3.4. HPS GICv3 ITS unable to access physical memory larger than 32 bits causing MSI-X Interrupt failure
2.1.3.5. SD/eMMC Host Controller Capabilities Register provides incorrect information with regard to 8-bit Embedded Device Support
2.1.3.2. USB 3.1 Controller Device Drops eSS ISOC Data if the ITP Delta Value is Greater than 63 units
Description
This issue occurs when the USB 3.1 controller is in device mode and positioned three or more hierarchy levels away from the external host controller. In this situation, the eSS device's ISOC endpoints do not function. You might experience data drops if you connect more than 63 USB devices in a USB hub tree with more than 3 levels.
Workaround
Connect the device up to 2 levels away from the external host controller.
| Devices Affected | Planned Fix |
|---|---|
|
No planned fix |