Agilex™ 7 M-Series Known Issue List

ID 851750
Date 9/29/2025
Public
Document Table of Contents

2. Known Issue List for Devices

Table 2.  Device Issues
Issue Affected Devices (OPN) Planned Fix (OPN) Document Update Notification
FPGA
F-Tile
Requirement for F-Tile Devices which are Powered and Unconfigured

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

(AGMx0xxR31Bxxxx)

(AGMx0xxR47Bxxxx)

None N/A N/A
FGT PAM4 Compliance Support

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

(AGMx0xxR31Bxxxx)

(AGMx0xxR47Bxxxx)

Quartus® Prime Pro Edition software version 25.1.1 N/A N/A
FGT Transceivers Do Not Support Direct EXTEST JTAG Instruction in Boundary Scan Test

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

(AGMx0xxR31Bxxxx)

(AGMx0xxR47Bxxxx)

None N/A N/A
F-Tile: Unsuccessful TX Equalization

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

(AGMx0xxR31Bxxxx)

(AGMx0xxR47Bxxxx)

None N/A N/A
Link May Not Downgrade With Corrupt Lanes (F-Tile)

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

(AGMx0xxR31Bxxxx)

(AGMx0xxR47Bxxxx)

None N/A N/A
Occasional Equalization Timeout or PCIe Link Training Failure to Achieve Expected Link Speed during Link Disable, Hot Reset, and Speed Change

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

(AGMx0xxR31Bxxxx)

(AGMx0xxR47Bxxxx)

None N/A N/A
Link Fault Detection window of the F-Tile Ethernet Hard IP in 10GE-1 or 25GE-1 mode

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

(AGMx0xxR31Bxxxx)

(AGMx0xxR47Bxxxx)

None N/A N/A
FHT PMA Transmitter-to-Receiver Internal Serial Loopback operation for error-free BER results

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

(AGMx0xxR31Bxxxx)

(AGMx0xxR47Bxxxx)

None N/A N/A
F-Tile Ethernet Hard IP rst_tx_stats and rst_rx_stats register bits might not function correctly

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

(AGMx0xxR31Bxxxx)

(AGMx0xxR47Bxxxx)

None N/A N/A
F-Tile Ethernet Hard IP force_rf register bit might not function correctly

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

(AGMx0xxR31Bxxxx)

(AGMx0xxR47Bxxxx)

None N/A N/A
F-Tile Ethernet Hard IP tx_pause_request register bit might not function correctly

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

(AGMx0xxR31Bxxxx)

(AGMx0xxR47Bxxxx)

None N/A N/A
F-Tile Ethernet Hard IP PTP statistics might not clear correctly

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

(AGMx0xxR31Bxxxx)

(AGMx0xxR47Bxxxx)

None N/A N/A
F-Tile Ethernet Hard IP unable to achieve 100% throughput with some variants

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

(AGMx0xxR31Bxxxx)

(AGMx0xxR47Bxxxx)

None N/A N/A
F-Tile 400G Ethernet IP RX Priority Flow Control Issue

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

(AGMx0xxR31Bxxxx)

(AGMx0xxR47Bxxxx)

Future release of Quartus® Prime Pro Edition software N/A N/A
F-Tile Ethernet Hard IP Bidirectional Link Fault Signaling Issue

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

(AGMx0xxR31Bxxxx)

(AGMx0xxR47Bxxxx)

Quartus® Prime Pro Edition software version 25.1.1 N/A N/A
F-Tile SDI II IP and F-Tile PMA/FEC Direct PHY IP with “SDI” configuration rule are not of production quality

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

(AGMx0xxR31Bxxxx)

(AGMx0xxR47Bxxxx)

Future release of Quartus® Prime Pro Edition software N/A N/A
F-Tile HDMI IP and F-Tile PMA/FEC Direct PHY IP with "HDMI" configuration rule are not of production quality

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

(AGMx0xxR31Bxxxx)

(AGMx0xxR47Bxxxx)

Future release of Quartus® Prime Pro Edition software N/A N/A
Ethernet Auto-Negotiation and Link Training (AN/LT) designs on F-Tile FGT may not link up when using Quartus Prime Pro Edition software version 25.1.1 and 25.3

Agilex™ 7 M-Series production devices

AGMxxxxxxxxxxxx

This issue is planned to be fixed in a future release of the Quartus® Prime Pro Edition software N/A N/A
IEEE 802.3-2022 50GBASE-KR compliance testing instability during Link Training (LT)

Agilex™ 7 M-Series production devices

AGMxxxxxxxxxxxx

This issue is planned to be fixed in a future release of the Quartus® Prime Pro Edition software N/A N/A
R-Tile
Gen3/Gen4 link might be established without successfully performing Transmit Equalization (TX EQ)

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

None N/A N/A
Link may not downgrade with corrupt lanes

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

None N/A N/A
Malformed TLP incorrectly flagged as ECRC error

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

None N/A N/A
Assertion of PERST / warm reset during the Functional Level Reset results in PCIe Link Failure

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

None N/A N/A
No Support for Page Request Services in Port 2 and Port 3 of 4x4 Configuration

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

None N/A N/A
Multiple Fatal Error Messages

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

None N/A N/A
PCIe x4 cores may report Uncorrectable Fatal Error or Malformed TLP

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

None N/A N/A
Receiver Errors logged during back-to-back Secondary Bus Resets (SBR) operations when running at Gen 2 speed

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

None N/A N/A
Polling.Active time out during Link Disable-Enable loop tests

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

None N/A N/A
CXL 1.1 version does not support uncorrectable error reporting when receiving two LLCTRL-Init packet

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

None N/A N/A
R-tile might report Fatal Error in the Advance Error Reporting (AER) registers when using Address Translation Service (ATS)

Agilex™ 7M-Series production devices

(AGMx0xxR47Axxxx)

This issue is planned to be fixed in a future release of the Quartus® Prime Pro Edition software N/A N/A
EMIF
DDR5 x32 + user bits through NoC is not supported

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

(AGMx0xxR31Bxxxx)

(AGMx0xxR47Bxxxx)

None N/A N/A
PhyMux EMIF lockstep pinout configurations Restrictions

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

(AGMx0xxR31Bxxxx)

(AGMx0xxR47Bxxxx)

None N/A N/A
GPIO-B blocked in mixed GPIO-B/EMIF use cases

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

(AGMx0xxR31Bxxxx)

(AGMx0xxR47Bxxxx)

None N/A N/A
DDR4 rDBI is not working

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

(AGMx0xxR31Bxxxx)

(AGMx0xxR47Bxxxx)

None N/A N/A
LPDDR5 and DDR5 reduced sequential write/read bandwidth when using Fabric Sync Fabric direct mode in x16 2-channel configuration

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

(AGMx0xxR31Bxxxx)

(AGMx0xxR47Bxxxx)

None N/A N/A
LPDDR5 and DDR5 maximum bandwidth for sequential short write is limited

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

(AGMx0xxR31Bxxxx)

(AGMx0xxR47Bxxxx)

None N/A N/A
LPDDR5 and DDR5 controller does not support non-aligned transactions

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

(AGMx0xxR31Bxxxx)

(AGMx0xxR47Bxxxx)

None N/A N/A
Configuration and Security
AS Fast mode BootROM delay

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

(AGMx0xxR31Bxxxx)

(AGMx0xxR47Bxxxx)

None N/A N/A
Fabric NoC
Lower than expected performance with Fabric NoC-enabled design

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

(AGMx0xxR31Bxxxx)

(AGMx0xxR47Bxxxx)

None N/A N/A
Device Power Supply, Core, I/O
I/O PLL reference clock frequency and duty cycle specification update

Agilex™ 7 M-Series production devices

(AGMx0xxR47Axxxx)

(AGMx0xxR31Bxxxx)

(AGMx0xxR47Bxxxx)

None N/A N/A
HPS
HPS EMAC RX Interface In Unresponsive State

Agilex™ 7 M-Series production devices

(AGM[B,E,F]0xxR47Axxxx)

(AGMB0xxR31Bxxxx)

(AGMF0xxR47Bxxxx)

None N/A N/A