2. Known Issue List for Devices
Issue | Affected Devices (OPN) | Planned Fix (OPN) | Document Update | Notification |
---|---|---|---|---|
FPGA | ||||
F-Tile | ||||
Requirement for F-Tile Devices which are Powered and Unconfigured | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) (AGMx0xxR31Bxxxx) (AGMx0xxR47Bxxxx) |
None | N/A | N/A |
FGT PAM4 Compliance Support | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) (AGMx0xxR31Bxxxx) (AGMx0xxR47Bxxxx) |
Quartus® Prime Pro Edition software version 25.1.1 | N/A | N/A |
FGT Transceivers Do Not Support Direct EXTEST JTAG Instruction in Boundary Scan Test | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) (AGMx0xxR31Bxxxx) (AGMx0xxR47Bxxxx) |
None | N/A | N/A |
F-Tile: Unsuccessful TX Equalization | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) (AGMx0xxR31Bxxxx) (AGMx0xxR47Bxxxx) |
None | N/A | N/A |
Link May Not Downgrade With Corrupt Lanes (F-Tile) | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) (AGMx0xxR31Bxxxx) (AGMx0xxR47Bxxxx) |
None | N/A | N/A |
Occasional Equalization Timeout or PCIe Link Training Failure to Achieve Expected Link Speed during Link Disable, Hot Reset, and Speed Change | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) (AGMx0xxR31Bxxxx) (AGMx0xxR47Bxxxx) |
None | N/A | N/A |
Link Fault Detection window of the F-Tile Ethernet Hard IP in 10GE-1 or 25GE-1 mode | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) (AGMx0xxR31Bxxxx) (AGMx0xxR47Bxxxx) |
None | N/A | N/A |
FHT PMA Transmitter-to-Receiver Internal Serial Loopback operation for error-free BER results | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) (AGMx0xxR31Bxxxx) (AGMx0xxR47Bxxxx) |
None | N/A | N/A |
F-Tile Ethernet Hard IP rst_tx_stats and rst_rx_stats register bits might not function correctly | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) (AGMx0xxR31Bxxxx) (AGMx0xxR47Bxxxx) |
None | N/A | N/A |
F-Tile Ethernet Hard IP force_rf register bit might not function correctly | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) (AGMx0xxR31Bxxxx) (AGMx0xxR47Bxxxx) |
None | N/A | N/A |
F-Tile Ethernet Hard IP tx_pause_request register bit might not function correctly | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) (AGMx0xxR31Bxxxx) (AGMx0xxR47Bxxxx) |
None | N/A | N/A |
F-Tile Ethernet Hard IP PTP statistics might not clear correctly | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) (AGMx0xxR31Bxxxx) (AGMx0xxR47Bxxxx) |
None | N/A | N/A |
F-Tile Ethernet Hard IP unable to achieve 100% throughput with some variants | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) (AGMx0xxR31Bxxxx) (AGMx0xxR47Bxxxx) |
None | N/A | N/A |
F-Tile 400G Ethernet IP RX Priority Flow Control Issue | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) (AGMx0xxR31Bxxxx) (AGMx0xxR47Bxxxx) |
Future release of Quartus® Prime Pro Edition software | N/A | N/A |
F-Tile Ethernet Hard IP Bidirectional Link Fault Signaling Issue | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) (AGMx0xxR31Bxxxx) (AGMx0xxR47Bxxxx) |
Quartus® Prime Pro Edition software version 25.1.1 | N/A | N/A |
F-Tile SDI II IP and F-Tile PMA/FEC Direct PHY IP with “SDI” configuration rule are not of production quality | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) (AGMx0xxR31Bxxxx) (AGMx0xxR47Bxxxx) |
Future release of Quartus® Prime Pro Edition software | N/A | N/A |
F-Tile HDMI IP and F-Tile PMA/FEC Direct PHY IP with "HDMI" configuration rule are not of production quality | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) (AGMx0xxR31Bxxxx) (AGMx0xxR47Bxxxx) |
Future release of Quartus® Prime Pro Edition software | N/A | N/A |
Ethernet Auto-Negotiation and Link Training (AN/LT) designs on F-Tile FGT may not link up when using Quartus Prime Pro Edition software version 25.1.1 and 25.3 | Agilex™ 7 M-Series production devices AGMxxxxxxxxxxxx |
This issue is planned to be fixed in a future release of the Quartus® Prime Pro Edition software | N/A | N/A |
IEEE 802.3-2022 50GBASE-KR compliance testing instability during Link Training (LT) | Agilex™ 7 M-Series production devices AGMxxxxxxxxxxxx |
This issue is planned to be fixed in a future release of the Quartus® Prime Pro Edition software | N/A | N/A |
R-Tile | ||||
Gen3/Gen4 link might be established without successfully performing Transmit Equalization (TX EQ) | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) |
None | N/A | N/A |
Link may not downgrade with corrupt lanes | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) |
None | N/A | N/A |
Malformed TLP incorrectly flagged as ECRC error | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) |
None | N/A | N/A |
Assertion of PERST / warm reset during the Functional Level Reset results in PCIe Link Failure | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) |
None | N/A | N/A |
No Support for Page Request Services in Port 2 and Port 3 of 4x4 Configuration | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) |
None | N/A | N/A |
Multiple Fatal Error Messages | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) |
None | N/A | N/A |
PCIe x4 cores may report Uncorrectable Fatal Error or Malformed TLP | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) |
None | N/A | N/A |
Receiver Errors logged during back-to-back Secondary Bus Resets (SBR) operations when running at Gen 2 speed | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) |
None | N/A | N/A |
Polling.Active time out during Link Disable-Enable loop tests | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) |
None | N/A | N/A |
CXL 1.1 version does not support uncorrectable error reporting when receiving two LLCTRL-Init packet | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) |
None | N/A | N/A |
R-tile might report Fatal Error in the Advance Error Reporting (AER) registers when using Address Translation Service (ATS) | Agilex™ 7M-Series production devices (AGMx0xxR47Axxxx) |
This issue is planned to be fixed in a future release of the Quartus® Prime Pro Edition software | N/A | N/A |
EMIF | ||||
DDR5 x32 + user bits through NoC is not supported | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) (AGMx0xxR31Bxxxx) (AGMx0xxR47Bxxxx) |
None | N/A | N/A |
PhyMux EMIF lockstep pinout configurations Restrictions | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) (AGMx0xxR31Bxxxx) (AGMx0xxR47Bxxxx) |
None | N/A | N/A |
GPIO-B blocked in mixed GPIO-B/EMIF use cases | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) (AGMx0xxR31Bxxxx) (AGMx0xxR47Bxxxx) |
None | N/A | N/A |
DDR4 rDBI is not working | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) (AGMx0xxR31Bxxxx) (AGMx0xxR47Bxxxx) |
None | N/A | N/A |
LPDDR5 and DDR5 reduced sequential write/read bandwidth when using Fabric Sync Fabric direct mode in x16 2-channel configuration | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) (AGMx0xxR31Bxxxx) (AGMx0xxR47Bxxxx) |
None | N/A | N/A |
LPDDR5 and DDR5 maximum bandwidth for sequential short write is limited | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) (AGMx0xxR31Bxxxx) (AGMx0xxR47Bxxxx) |
None | N/A | N/A |
LPDDR5 and DDR5 controller does not support non-aligned transactions | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) (AGMx0xxR31Bxxxx) (AGMx0xxR47Bxxxx) |
None | N/A | N/A |
Configuration and Security | ||||
AS Fast mode BootROM delay | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) (AGMx0xxR31Bxxxx) (AGMx0xxR47Bxxxx) |
None | N/A | N/A |
Fabric NoC | ||||
Lower than expected performance with Fabric NoC-enabled design | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) (AGMx0xxR31Bxxxx) (AGMx0xxR47Bxxxx) |
None | N/A | N/A |
Device Power Supply, Core, I/O | ||||
I/O PLL reference clock frequency and duty cycle specification update | Agilex™ 7 M-Series production devices (AGMx0xxR47Axxxx) (AGMx0xxR31Bxxxx) (AGMx0xxR47Bxxxx) |
None | N/A | N/A |
HPS | ||||
HPS EMAC RX Interface In Unresponsive State | Agilex™ 7 M-Series production devices (AGM[B,E,F]0xxR47Axxxx) (AGMB0xxR31Bxxxx) (AGMF0xxR47Bxxxx) |
None | N/A | N/A |