5.4. IP Parameters

This following table describes how to configure the fRSmartComp in IP Parameters Editors.
Table 64.  fRSmartComp Configuration
Parameter Name Description Default Value
Blind Window Period Number of clock cycles during which the comparator events are automatically masked by the fRSmartComp after CPU reset (between 10 and 65535). 1000
Default Timeout Period
Programmable Timeout value on reset exit or after a DISABLE command (between 0 and 255).
Note: 0 = timeout is OFF.
255
Enable Extended Reset Interface

Enable the optional Extended Reset Interface for Extended Reset Control.

When disabled, the fRSmartComp implements Basic Reset Control.
0 (Basic Reset Control)