Nios® V Processor: Lockstep Implementation User Guide

ID 833274
Date 4/17/2025
Public
Document Table of Contents

4.4.10. Alarm Fault Injection Control register - ERRCTRL_ALARM_INJ

Use the following register to control Alarm Fault injection.
Table 45.  Alarm Fault Injection Control register - ERRCTRL_ALARM_INJ
Bit Field Bits Access Type Default Value Description
Reserved [31:20] - - Reserved
ALARM19INJ [19] R/W 0

(No injection)

Alarm fault injection on ALARM19.
ALARM18INJ [18] R/W 0

(No injection)

Alarm fault injection on ALARM18.
ALARM17INJ [17] R/W 0

(No injection)

Alarm fault injection on ALARM17.
ALARM16INJ [16] R/W 0

(No injection)

Alarm fault injection on ALARM16.
Reserved [15:5] - - Reserved
ALARM4INJ [4] R/W 0

(No injection)

Alarm fault injection on ALARM4.
ALARM3INJ [3] R/W 0

(No injection)

Alarm fault injection on ALARM3.
ALARM2INJ [2] R/W 0

(No injection)

Alarm fault injection on ALARM2.
ALARM1INJ [1] R/W 0

(No injection)

Alarm fault injection on ALARM1.
ALARM0INJ [0] R/W 0

(No injection)