1. About the Nios® V Processor Lockstep
2. Overview
3. Controlling the Nios® V Processor Lockstep
4. Programming Model
5. Signals, Interfaces, and Build Parameters
6. Using Nios® V Processor Lock Step
A. Document Revision History for the Nios® V Processor: Lockstep Implementation User Guide
B. Appendix
4.4.1. CPUs’ Reset Control Register - DCLSM_CPURC
4.4.2. DCLSM Basic Control Register - DCLSM_CTRL
4.4.3. DCLSM Blind Window Control Register - DCLSM_BWCR
4.4.4. All Alarms’ Prior Alarms’ Fault Injection Register - ERRCTRL_ALL_ALARMS_PRIOR_AFI
4.4.5. INTREQ Configuration Register - ERRCTRL_INTREQ_CONF
4.4.6. Timeout Deadline and Status Register - ERRCTRL_TIMEOUT
4.4.7. Timeout Acknowledgment Register - ERRCTRL_TIMEOUT_ACK
4.4.8. Enable Key fRSmartComp Control Register - ERRCTRL_ENABLE_KEY
4.4.9. Root Fault Injection Control register - ERRCTRL_ROOT_INJ
4.4.10. Alarm Fault Injection Control register - ERRCTRL_ALARM_INJ
4.4.11. Event Mask Configuration register - ERRCTRL_MASKA and ERRCTRL_MASKB
4.4.12. Alarm Routing Configuration register - ERRCTRL_ROUTA and ERRCTRL_ROUTB
4.4.13. Error Controller PGO LOG Reset Control register - ERRCTRL_PGOLOGRST
4.4.14. PGO0 and PGO4 Configuration registers - ERRCTRL_PGO0 and ERRCTRL_PGO4
4.4.15. FN_MODEIN Control Register - ERRCTRL_FNMODEIN
4.4.16. FN_MODEOUT register - ERRCTRL_FNMODEOUT
4.4.17. All Alarms After Fault Injection - ERRCTRL_FNGIALARMS
4.4.18. Error Controller Context Register - ERRCTRL_FNGICTXT4
4.4.19. CMP Mismatch CONTEXT Registers - ERRCTRL_FNGICMPCTXT0 … ERRCTRL_FNGICMPCTXT3
4.4.20. STATISTICS registers: ERRCTRL_FNGISTAT0 and ERRCTRL_FNGISTAT4
4.4.21. State register - ERRCTRL_FNPERIPHGI4
5.1. Configuration Interface
The following table describes the Configuration Interface signals.
Signal Names | Width (bits) | Direction | Description |
---|---|---|---|
ADDRESS | 14 | Input | Word address for write and read transfers. 64 KB are used from this interface, therefore the width is 14 (bits). |
BYTEENABLE | 4 | Input | Enables specific byte lanes during transfers. |
READ | 1 | Input | Asserted to indicate a read transfer. |
READDATA | 32 | Output | Read data from the fRSmartComp. |
READDATAVALID | 1 | Output | Asserted by fRSmartComp to indicate that the read data signal contains valid data. |
WRITE | 1 | Input | Asserted to indicate a write transfer. |
WRITEDATA | 32 | Input | Write data to the fRSmartComp. |
WAITREQUEST | 1 | Output | Asserted by the fRSmartComp when it is unable to respond to a read or write request. |