Hard Processor System Technical Reference Manual: Agilex™ 5 SoCs
4.3.5.1. MMU-600 TCU Configuration Signals
The values of the configuration straps for the TCU are shown in the following table.
| Signal | Description | Value | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| sup_cohacc | This signal indicates whether the QTW interface is I/O coherent. Tie HIGH when the TCU is connected to a coherent interconnect. | 1 | ||||||||||||||
| sup_btm | This signal indicates whether the Broadcast TLB Maintenance is supported. Tie HIGH when the TCU is connected to an interconnect that supports DVM. | 1 | ||||||||||||||
| sup_sev | This signal indicates whether the Send Event mechanism is supported. Tie HIGH when the evento signal is connected. | 1 | ||||||||||||||
| sup_oas[2:0] | Output address size supported. 
        The encodings for this input are: 
         
 | 3’b010 | ||||||||||||||
| sec_override | When HIGH, certain registers are accessible to non-secure accesses from reset, as the TCU_SCR register settings describe. | 0 | ||||||||||||||
| ecorevnum[3:0] | Tie this signal to 0 unless directed otherwise by Arm. | 0b0000 |