1. About the GTS Serial Lite IV IP User Guide: Agilex™ 5 E-Series/D-Series and Agilex™ 3 Devices
2. GTS Serial Lite IV IP Overview
3. Getting Started
4. Functional Description
5. Parameters
6. GTS Serial Lite IV IP Interface Signals
7. Designing with GTS Serial Lite IV IP
8. Document Revision History for the GTS Serial Lite IV IP User Guide
6.5. PMA/PCS Signals
| Name | Width | Direction | Clock Domain | Description |
|---|---|---|---|---|
tx_pll_locked |
N | Output | Asynchronous | When asserted, indicates the TX PLL has achieved lock status. |
tx_serial_data |
N | Output | TX serial clock | TX serial pins. |
rx_serial_data |
N | Input | RX serial clock | RX serial pins. |
| phy_rx_block_lock | N | Output | Asynchronous | When asserted, indicates that the 66b block alignment has completed for the lanes. |
| rx_cdr_lock | N | Output | Asynchronous | When asserted, indicates that the recovered clocks are locked to data. |
| phy_rx_pcs_ready | N | Output | Asynchronous | When asserted, indicates that the RX lanes of the corresponding Ethernet channel are fully aligned and ready to receive data. |
| phy_rx_hi_ber | N | Output | Asynchronous | When asserted, indicates that the RX PCS of the corresponding Ethernet channel is in a HI BER state. |
| sys_pll_locked | 1 | Input | Asynchronous | System/HVIO PLL lock signal used by HIP for monitoring purposes.
Connect this clock to either one of the following two sources:
|