Agilex™ 7 General-Purpose I/O User Guide: F-Series and I-Series
A newer version of this document is available. Customers should click here to go to the newest version.
Visible to Intel only — GUID: cnt1550567600271
Ixiasoft
Visible to Intel only — GUID: cnt1550567600271
Ixiasoft
2.4.2. True Differential Signaling I/O Termination
Use OCT with these I/O standards to save board space and cost. OCT reduces the number of external termination resistors usage. Refer to the F-Series and I-Series device pin-out files for more information about dedicated differential transmitter and receiver pins.
Section Content
True Differential Signaling I/O Standard OCT Termination
True Differential Signaling I/O Standard External Termination