2.1. Recommended Power-up Sequencing for MAX 10 ES Devices
To ensure the minimum current draw during power up and configuration for MAX® 10 dual supply ES devices, follow the recommended power-up sequence as shown in the figure below.
Figure 3. Recommended Power-up SequenceThe power rails in each group must be ramped up to a minimum of 90% of their full rail before the next group starts.