Agilex™ 7 F-Series and I-Series Known Issue List

ID 683584
Date 9/04/2025
Public
Document Table of Contents

2.1.1.12. FHT PMA Transmitter-to-Receiver Internal Serial Loopback operation for error-free BER results

Description

When using the FHT PMA Transmitter-to-Receiver Internal Serial Loopback mode of operation, you must ensure that no signal is being driven onto the receive serial pins of the PMA in order to obtain error-free BER results. If a signal is being driven onto the RX serial pins, the BER testing yields non-zero results.

Workaround

No workaround available.

Status

Table 14.  Device Status Table
Devices Affected Planned Fix
  • AGFxxxxxxxxxxxx
  • AGIxxxxxxxxxxxx
None