General-Purpose I/O User Guide: Agilex™ 3 FPGAs and SoCs
ID
847266
Date
4/07/2025
Public
A newer version of this document is available. Customers should click here to go to the newest version.
1. Agilex™ 3 General-Purpose I/O Overview
2. Agilex™ 3 HSIO Banks
3. Agilex™ 3 HVIO Banks
4. Agilex™ 3 HPS I/O Banks
5. Agilex™ 3 SDM I/O Banks
6. Agilex™ 3 I/O Troubleshooting Guidelines
7. GPIO FPGA IP
8. Programmable I/O Features Description
9. Document Revision History for the General-Purpose I/O User Guide: Agilex™ 3 FPGAs and SoCs
2.5.1. I/O Standard Placement Restrictions for True Differential I/Os
2.5.2. Placement Restrictions for True Differential and Single-Ended I/O Standards in the Same or Adjacent HSIO Bank
2.5.3. VREF Sources and Input Standards Grouping
2.5.4. HSIO Pin Restrictions for External Memory Interfaces
2.5.5. RZQ Pin Requirement
2.5.6. I/O Standards Implementation Based on VCCIO_PIO Voltages
2.5.7. I/O Standard Selection and I/O Bank Supply Compatibility Check
2.5.8. Simultaneous Switching Noise
2.5.9. HPS Shared I/O Requirements
2.5.10. Clocking Requirements
2.5.11. SDM Shared I/O Requirements
2.5.12. Unused Pins
2.5.13. VCCIO_PIO Supply for Unused HSIO Banks
2.5.14. HSIO Pins During Power Sequencing
2.5.15. Drive Strength Requirement for HSIO Input Pins
2.5.16. Maximum DC Current Restrictions
2.5.17. 1.05 V, 1.1 V, or 1.2 V I/O Interface Voltage Level Compatibility
2.5.18. Connection to True Differential Signaling Input Buffers During Device Reconfiguration
2.5.19. Implementing a Pseudo Open Drain
2.5.20. Allowed Duration for Using RT OCT
2.5.21. Single-Ended Strobe Signal Differential Pin Pair Restriction
2.5.22. Implementing SLVS-400 or DPHY I/O Standard with 1.1 V VCCIO_PIO
2.4.1.1.3. Dynamic OCT
Dynamic OCT is useful for terminating a high performance bidirectional path by optimizing signal integrity depending on data direction. Dynamic OCT reduces power usage because the termination switches on only during input operations.
Dynamic OCT | Bidirectional I/O | State |
---|---|---|
Dynamic RT OCT | Receiver | On |
Driver | Off | |
Dynamic RS OCT | Receiver | Off |
Driver | On |
Figure 11. Dynamic RT OCT in Agilex™ 3 Devices