Visible to Intel only — GUID: wtw1459241579322
Ixiasoft
Power Module Grouping
This design example uses three power modules. Each power module powers different power rails for the Intel® Arria® 10 device.
Group | Nominal Value (V) | Power Rails on Intel® Arria® 10 Device |
---|---|---|
1 | 0.9 | VCC, VCCP, VCCR_GXB, VCCERAM |
2 | 1.8 | VCCPT, VCCH_GXB, VCCA_PLL |
3 | 1.8 | VCCPGM, VCCIO |
Each power group has different threshold and ramp voltage limits. The preset values are defined in the program in main.h. You can update the threshold and ramp voltage via UART using the THRESHOLD or RAMP command.