Intel® Quartus® Prime Pro Edition Settings File Reference Manual

ID 683296
Date 6/26/2023
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

XCVR_C10_RX_ADP_CTLE_EQZ_1S_SEL

A logic option that allows you to control the amount of AC gain on the one-stage equalizer. The amount of AC gain is propotional to the setting where '0' gives the lowest AC gain and '15' gives the largest AC gain. This option is only valid when equalizer operates in manual mode.

Type

Enumeration

Values

  • RADP_CTLE_EQZ_1S_SEL_0
  • RADP_CTLE_EQZ_1S_SEL_1
  • RADP_CTLE_EQZ_1S_SEL_10
  • RADP_CTLE_EQZ_1S_SEL_11
  • RADP_CTLE_EQZ_1S_SEL_12
  • RADP_CTLE_EQZ_1S_SEL_13
  • RADP_CTLE_EQZ_1S_SEL_14
  • RADP_CTLE_EQZ_1S_SEL_15
  • RADP_CTLE_EQZ_1S_SEL_2
  • RADP_CTLE_EQZ_1S_SEL_3
  • RADP_CTLE_EQZ_1S_SEL_4
  • RADP_CTLE_EQZ_1S_SEL_5
  • RADP_CTLE_EQZ_1S_SEL_6
  • RADP_CTLE_EQZ_1S_SEL_7
  • RADP_CTLE_EQZ_1S_SEL_8
  • RADP_CTLE_EQZ_1S_SEL_9

Device Support

  • Intel® Cyclone® 10 GX

Notes

Syntax

set_instance_assignment -name XCVR_C10_RX_ADP_CTLE_EQZ_1S_SEL -to <to> -entity <entity name> <value>