Skip To Main Content
Support Knowledge Base

PSU 1 and 2: Failure detected

Content Type: Error Messages   |   Article ID: 000029201   |   Last Reviewed: 07/08/2021

Environment

Intel® Rack Scale Design Direct

Description

The System Event Log (SEL) would report this as follows:

{{{
4 | 06/21/2018 | 13:31:31 | Power Supply PSU 2 Status | Failure detected | Asserted
5 | 06/21/2018 | 13:31:33 | Power Supply PSU 1 Status | Failure detected | Asserted
}}}


The Sensor Data Record (SDR) would show the following events (the below are just examples how these would be reported):

PSU 1 Status | B6h | ok | 144.96 | Presence detected, Failure detected
PSU 2 Status | B7h | ok | 144.97 | Presence detected, Failure detected


Note: PSU stands for Power Supply Unit.
 

Resolution

If the system still boots up, proceed as follows:
1. Clear the event log.  For this, refer to the "Clearing the SEL Viewer Utility" section in the Intel System Event Log (SEL) Viewer Utility User Guide
2. Stress-test the node.

Otherwise, contact Support with the system event log* for diagnosis.

* How to Extract and Read the System Event Log (SEL) for Intel® Server Boards

Related Products

This article applies to 1 products.