Intel® Server Board D40AMP Family BIOS and Firmware Update Package for UEFI

723030
2/22/2022

Introduction

This download record contains the BIOS and firmware update package for the Intel® Server Board D40AMP Family for UEFI (R01.02.0006)

Available Downloads

  • OS Independent
  • Size: 24.5 MB
  • SHA1: 9950A057DE9FC2305EA459901FC3E1120F1F8481

Detailed Description

Overview

This download record contains the BIOS and firmware update package for the Intel® Server Board D40AMP Family and appropriate Intel® Server System D40AMP Family —for use with Intel's technology-embedded Unified Extensible Firmware Interface (UEFI) shell.

Purpose

uEFI System Update Package (SUP) Installation and Operation Instructions

 

Released - January 7, 2022

********************************************************************************

This update package includes the following production level system software updates and update utilities:

  System BIOS  - SE5C620.86B.01.02.0006

  ME Firmware  - 04.04.04.56

  BMC Firmware  - 2.87.3ccd0377.

  FRUSDR     - 0.20

  DCPMM     - 2.2.0.1553

  CPLD      - v1P7

   sysfwupdt.efi - Version 14.2 Build 11

 

Supported Products

Intel® Server D40AMP Family

 

Important NOTES: 

  • All updates provided in this package are installed using the embedded uEFI operating environment only.
  • Do not modify any of the script files. The scripts as written will provide the most reliable update experience. 
  • If for any reason the System BIOS, BMC Firmware, or FRU&SDR data need to be re-installed after the initial update has been performed, the package does include standalone script files that can be run individually. 

These files include:

UpdBIOS_AMP.nsh, UpdD40AMP.nsh, AMP_CPLD_update_script.nsh, ampFwUpdateBMC.nsh, UpdatePmemFW.nsh. 

Do NOT use these files until after the system has been updated initially using the startup.nsh file.

 

System software requirements

To update the system software stack to the versions included in this update package, the system software stack currently installed on the target server system MUST meet the following, or else the update may fail:

  • System BIOS   - Production version SE5C620.86B.01.02.0002 or later
  • BMC Firmware  - Production version 2.87.5fef98fb or later
  • FRUSDR      - Production version 0.19 or later 
  • CPLD - Production version 1.6 
  • Pmem     - 2.2.0.1553 

For pre-production hardware and software support requirements, contact Intel for details

 

Important information for the update procedure

Due to the new structure of FW using PFR, the update process takes longer then on previous generation of Intel server systems. The first time the server is rebooted 

after BMC/FRUSDR/DCPMM/CPLD/BIOS FW has been updated, it will take around 12 minutes to conclude the update process. During that period the screen will be off and 

blue ID LED will be solid on while system status LED will blink green/yellow. Once the process is fuly completed the ID LED will be off and system will turn on again. 

This is an expected behavior and will only present on the first reboot after FW update.

 

Intel highly recommends reading the Readme and Update Instructions.txt in its entirety before performing the system update. Verifying that your system meets the documented requirements will ensure a successful update and provide the most reliable system functionality after the update has completed.

 

This download is valid for the product(s) listed below.

Product and Performance Information

1

Intel is in the process of removing non-inclusive language from our current documentation, user interfaces, and code. Please note that retroactive changes are not always possible, and some non-inclusive language may remain in older documentation, user interfaces, and code.