Hard Processor System Remote System Update User Guide: Agilex™ 5 SoCs
ID
852610
Date
4/18/2025
Public
1. Overview
2. Use Cases
3. Quad SPI Flash Layout
4. Quartus® Prime Software and Tool Support
5. Software Support
6. Flash Corruption - Detection and Recovery
7. Remote System Update Example
8. Version Compatibility Considerations
9. Revision History for the Hard Processor System Remote System Update User Guide: Agilex™ 5 SoCs
A. Configuration Flow Diagrams
B. RSU Status and Error Codes
C. U-Boot RSU Reference Information
D. LIBRSU Reference Information
E. Combined Application Images
2.1. Manufacturing
2.2. Application Image Boot
2.3. Factory Image Boot
2.4. Modifying the List of Application Images
2.5. Querying RSU Status
2.6. Loading a Specific Image
2.7. Protected Access to Flash
2.8. Remote System Update Watchdog
2.9. RSU Notify
2.10. Updating the Factory Image
2.11. Updating the Decision Firmware
2.12. Retrying when Configuration Fails
2.13. Querying the Decision Firmware Version
C.6.1. rsu_init
C.6.2. rsu_exit
C.6.3. rsu_slot_count
C.6.4. rsu_slot_by_name
C.6.5. rsu_slot_get_info
C.6.6. rsu_slot_size
C.6.7. rsu_slot_priority
C.6.8. rsu_slot_erase
C.6.9. rsu_slot_program_buf
C.6.10. rsu_slot_program_factory_update_buf
C.6.11. rsu_slot_program_buf_raw
C.6.12. rsu_slot_verify_buf
C.6.13. rsu_slot_verify_buf_raw
C.6.14. rsu_slot_enable
C.6.15. rsu_slot_disable
C.6.16. rsu_slot_load
C.6.17. rsu_slot_load_factory
C.6.18. rsu_slot_rename
C.6.19. rsu_slot_delete
C.6.20. rsu_slot_create
C.6.21. rsu_status_log
C.6.22. rsu_notify
C.6.23. rsu_clear_error_status
C.6.24. rsu_reset_retry_counter
C.6.25. rsu_dcmf_version
C.6.26. rsu_max_retry
C.6.27. rsu_dcmf_status
C.6.28. rsu_create_empty_cpb
C.6.29. rsu_restore_cpb
C.6.30. rsu_save_cpb
C.6.31. rsu_restore_spt
C.6.32. rsu_save_spt
C.6.33. rsu_running_factory
C.7.1. dtb
C.7.2. list
C.7.3. slot_by_name
C.7.4. slot_count
C.7.5. slot_disable
C.7.6. slot_enable
C.7.7. slot_erase
C.7.8. slot_get_info
C.7.9. slot_load
C.7.10. slot_load_factory
C.7.11. slot_priority
C.7.12. slot_program_buf
C.7.13. slot_program_buf_raw
C.7.14. slot_program_factory_update_buf
C.7.15. slot_rename
C.7.16. slot_delete
C.7.17. slot_create
C.7.18. slot_size
C.7.19. slot_verify_buf
C.7.20. slot_verify_buf_raw
C.7.21. status_log
C.7.22. update
C.7.23. notify
C.7.24. clear_error_status
C.7.25. reset_retry_counter
C.7.26. display_dcmf_version
C.7.27. display_dcmf_status
C.7.28. display_max_retry
C.7.29. restore_spt
C.7.30. save_spt
C.7.31. create_empty_cpb
C.7.32. restore_cpb
C.7.33. save_cpb
C.7.34. check_running_factory
D.6.1. rsu_slot_priority
D.6.2. rsu_slot_erase
D.6.3. rsu_slot_program_buf
D.6.4. rsu_slot_program_factory_update_buf
D.6.5. rsu_slot_program_file
D.6.6. rsu_slot_program_factory_update_file
D.6.7. rsu_slot_program_buf_raw
D.6.8. rsu_slot_program_file_raw
D.6.9. rsu_slot_verify_buf
D.6.10. rsu_slot_verify_file
D.6.11. rsu_slot_verify_buf_raw
D.6.12. rsu_slot_verify_file_raw
D.6.13. rsu_slot_program_callback
D.6.14. rsu_slot_program_callback_raw
D.6.15. rsu_slot_verify_callback
D.6.16. rsu_slot_verify_callback_raw
D.6.17. rsu_slot_copy_to_file
D.6.18. rsu_slot_enable
D.6.19. rsu_slot_disable
D.6.20. rsu_slot_load_after_reboot
D.6.21. rsu_slot_load_factory_after_reboot
D.6.22. rsu_slot_rename
D.6.23. rsu_slot_delete
D.6.24. rsu_slot_create
D.6.25. rsu_status_log
D.6.26. rsu_notify
D.6.27. rsu_clear_error_status
D.6.28. rsu_reset_retry_counter
D.6.29. rsu_dcmf_version
D.6.30. rsu_max_retry
D.6.31. rsu_dcmf_status
D.6.32. rsu_save_spt
D.6.33. rsu_restore_spt
D.6.34. rsu_save_cpb
D.6.35. rsu_create_empty_cpb
D.6.36. rsu_restore_cpb
D.6.37. rsu_running_factory
D.7.1. count
D.7.2. list
D.7.3. size
D.7.4. priority
D.7.5. enable
D.7.6. disable
D.7.7. request
D.7.8. request-factory
D.7.9. erase
D.7.10. add
D.7.11. add-factory-update
D.7.12. add-raw
D.7.13. verify
D.7.14. verify-raw
D.7.15. copy
D.7.16. log
D.7.17. notify
D.7.18. clear-error-status
D.7.19. reset-retry-counter
D.7.20. display-dcmf-version
D.7.21. display-dcmf-status
D.7.22. display-max-retry
D.7.23. create-slot
D.7.24. delete-slot
D.7.25. restore-spt
D.7.26. save-spt
D.7.27. create-empty-cpb
D.7.28. restore-cpb
D.7.29. save-cpb
D.7.30. check-running-factory
D.7.31. help
4.2.2. Bitswap Option
The Quartus® Prime Programmer assumes by default that the binary files have the bits in the reversed order for each byte. Because of this, the bitswap=on option must be enabled as follows:
- For each input binary file (.bin and .hex files are supported).
- For each output RPD file (full flash images, application images, factory update images, decision firmware update images, and combined application images).
The bitswap option is used accordingly in the examples shown in this document.