1. About the F-Tile Triple-Speed Ethernet IP User Guide
2. About F-Tile Triple-Speed Ethernet IP
3. Getting Started
4. Parameter Settings
5. Functional Description
6. Configuration Register Space
7. Interface Signals
8. Design Considerations
9. Timing Constraints
10. Software Programming Interface
11. F-Tile Triple-Speed Ethernet IP User Guide Archives
12. Document Revision History for the F-Tile Triple-Speed Ethernet IP User Guide
A. Ethernet Frame Format
B. Simulation Parameters
5.1.1. MAC Architecture
5.1.2. MAC Interfaces
5.1.3. MAC Transmit Datapath
5.1.4. MAC Receive Datapath
5.1.5. MAC Transmit and Receive Latencies
5.1.6. FIFO Buffer Thresholds
5.1.7. Congestion and Flow Control
5.1.8. Magic Packets
5.1.9. MAC Local Loopback
5.1.10. MAC Reset
5.1.11. PHY Management (MDIO)
5.1.12. Connecting MAC to External PHYs
6.1.1. Base Configuration Registers (Dword Offset 0x00 – 0x17)
6.1.2. Statistics Counters (Dword Offset 0x18 – 0x38)
6.1.3. Transmit and Receive Command Registers (Dword Offset 0x3A – 0x3B)
6.1.4. Supplementary Address (Dword Offset 0xC0 – 0xC7)
6.1.5. IEEE 1588v2 Feature (Dword Offset 0xD0 – 0xD6)
6.1.6. Deterministic Latency (Dword Offset 0xE1– 0xE3)
6.1.7. IEEE 1588v2 Feature PMA Delay
7.1.1. 10/100/1000 Ethernet MAC Signals
7.1.2. 10/100/1000 Multiport Ethernet MAC Signals
7.1.3. 10/100/1000 Ethernet MAC with 1000BASE-X/SGMII PCS Signals
7.1.4. 10/100/1000 Ethernet MAC with 1000BASE-X/SGMII 2XTBI PCS and Embedded PMA Signals (F-Tile)
7.1.5. 10/100/1000 Ethernet MAC Without Internal FIFO Buffers with 1000BASE-X/SGMII 2XTBI PCS Signals
7.1.6. 10/100/1000 Ethernet MAC Without Internal FIFO Buffers with IEEE 1588v2 , 1000BASE-X/SGMII 2XTBI PCS, and Embedded Serial PMA Signals
7.1.7. 10/100/1000 Multiport Ethernet MAC with 1000BASE-X/SGMII PCS Signals
7.1.8. 10/100/1000 Ethernet MAC with 1000BASE-X/SGMII PCS and Embedded PMA Signals
7.1.9. 10/100/1000 Multiport Ethernet MAC with 1000BASE-X/SGMII PCS and Embedded PMA Signals
7.1.10. 1000BASE-X/SGMII PCS Signals
7.1.11. 1000BASE-X/SGMII 2XTBI PCS Signals
7.1.12. 1000BASE-X/SGMII PCS and PMA Signals
7.1.1.1. Clock and Reset Signals
7.1.1.2. Clock Enabler Signals
7.1.1.3. MAC Control Interface Signals
7.1.1.4. MAC Status Signals
7.1.1.5. MAC Receive Interface Signals
7.1.1.6. MAC Transmit Interface Signals
7.1.1.7. Pause and Magic Packet Signals
7.1.1.8. MII/GMII/RGMII Signals
7.1.1.9. PHY Management Signals
7.1.1.10. ECC Status Signals
7.1.6.1. Deterministic Latency Clock Signals
7.1.6.2. IEEE 1588v2 RX Timestamp Signals
7.1.6.3. IEEE 1588v2 TX Timestamp Signals
7.1.6.4. IEEE 1588v2 TX Timestamp Request Signals
7.1.6.5. IEEE 1588v2 TX Insert Control Timestamp Signals
7.1.6.6. IEEE 1588v2 Time-of-Day (TOD) Clock Interface Signals
7.1.6.7. IEEE 1588v2 PCS Phase Measurement Clock Signal
10.6.1. alt_tse_mac_get_common_speed()
10.6.2. alt_tse_mac_set_common_speed()
10.6.3. alt_tse_phy_add_profile()
10.6.4. alt_tse_system_add_sys()
10.6.5. triple_speed_ethernet_init()
10.6.6. tse_mac_close()
10.6.7. tse_mac_raw_send()
10.6.8. tse_mac_setGMII mode()
10.6.9. tse_mac_setMIImode()
10.6.10. tse_mac_SwReset()
5.1.11. PHY Management (MDIO)
This module implements the standard MDIO specification, IEEE 803.2 standard Clause 22, to access the PHY device management registers, and supports up to 32 PHY devices.
To access each PHY device, write the PHY address to the MDIO register (mdio_addr0/1) followed by the transaction data (MDIO Space 0/1). For faster access, the MAC function allows up to two PHY devices to be mapped in its register space at any one time. Subsequent transactions to the same PHYs do not require writing the PHY addresses to the register space thus reducing the transaction overhead. You can access the MDIO registers via the Avalon® memory-mapped interface.
For more information about the registers of a PHY device, refer to the specification provided with the device.
For more information about the MDIO registers, refer to the MAC Configuration Register Space section.
Related Information