Triple-Speed Ethernet Intel® FPGA IP User Guide

ID 683402
Date 10/04/2021
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

5.2.2. Status Register (Word Offset 0x01)

Table 49.  Status Register Bit Descriptions
Bit Name R/W Description
0 EXTENDED_CAPABILITY RO A value of 1 indicates that the PCS function supports extended registers.
1 JABBER_DETECT Unused. Always set to 0.
2 LINK_STATUS RO A value of 1 indicates that a valid link is established. A value of 0 indicates an invalid link.

If the link synchronization is lost, a 0 is latched.

3 AUTO_NEGOTIATION_ABILITY RO A value of 1 indicates that the PCS function supports auto-negotiation.
4 REMOTE_FAULT Unused. Always set to 0.
5 AUTO_NEGOTIATION_COMPLETE RO A value of 1 indicates the following status:
  • The auto-negotiation process is completed.
  • The auto-negotiation control registers are valid.
6 MF_PREAMBLE_SUPPRESSION Unused. Always set to 0.
7 UNIDIRECTIONAL_ABILITY RO A value of 1 indicates that the PCS is able to transmit from MII/GMII regardless of whether the PCS has established a valid link.
8 EXTENDED_STATUS Unused. Always set to 0.
9 100BASET2_HALF_DUPLEX RO The PCS function does not support 100Base-T2, 10-Mbps, 100BASE-X, and 100Base-T4 operation. Always set to 0.
10 100BASET2_FULL_DUPLEX
11 10MBPS_HALF_DUPLEX
12 10MBPS_FULL_DUPLEX
13 100BASE-X_HALF_DUPLEX
14 100BASE-X_FULL_DUPLEX
15 100BASE-T4