Article ID: 000095342 Content Type: Error Messages Last Reviewed: 08/09/2023

Why does Intel Agilex® 7 FPGA F-Series, I-series, and M-series hang when performing recoverable configuration error?

Environment

    Intel® Quartus® Prime Design Software
    Serial Flash Controller Intel® FPGA IP
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

This behavior might be seen when Intel Agilex® 7 FPGAs AGF019, AGF023, AGI019, AGI023, AGI040 (ES), AGI041 (ES), and AGM039 (ES) try to perform recoverable reconfiguration due to configuration error if the nCONFIG signal is asserted less than 10 ms after nSTATUS signal goes low.

Refer to Intel Agilex® 7 Configuration User Guide (PDF) and Intel Agilex® 7 FPGAs and SoCs Device Data Sheet: F-Series and I-Series (PDF) for more details on the configuration timing diagram. 

 

 

Resolution

To work around this problem in the Intel® Quartus® Prime Pro Edition Software version before 23.1, ensure that the nCONFIG signal is asserted after more than 10 ms after the nSTATUS signal goes low.

A patch is available to fix this problem for the Intel® Quartus® Prime Pro Edition Software version 23.1. Please contact the regional application engineer to download patch 0.11fw.

This problem is fixed starting with the Intel® Quartus® Prime Pro Edition Software version 23.2.

 

To get the patch file, file an IPS case to Application Engineering. ACS patch number 6944. 

Related Products

This article applies to 1 products

Intel Agilex® 7 FPGAs and SoC FPGAs

1