Article ID: 000092354 Content Type: Troubleshooting Last Reviewed: 06/15/2023

Why can’t I configure all Intel Agilex®devices over Avalon® streaming, JTAG, Active Serial, or Remote System Update when using the Intel® Quartus® Prime Pro Edition Software version 22.3?                                                             

Environment

    Intel® Quartus® Prime Pro Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 22.3, you might experience problem with Avalon® streaming configuration, JTAG configuration, Active Serial configuration, and Remote System Update with certain Intel Agilex® devices.

The following table shows the list of affected devices:  

Affected Device FamilyDevice Density or OPN
Intel Agilex® FPGA I-SeriesAGI 035
AGI 040

     

 

Resolution

To work around this problem, download and install the patch for the Intel® Quartus® Prime Pro Edition Software v22.3.

 

Download and install Patch for version 22.3 from the appropriate link below.

Related Products

This article applies to 1 products

Intel Agilex® 7 FPGAs and SoC FPGAs

1