Article ID: 000091493 Content Type: Error Messages Last Reviewed: 07/19/2022

Why does CvP fail to recover in Intel® Agilex™ devices when updating the core with bitstreams built from different versions of the Intel® Quartus® Prime Pro Edition Software?

Environment

  • Intel® Quartus® Prime Pro Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 22.2 and earlier, CvP may fail to recover when trying to load a CvP bitstream built from a different version than the one running on the Intel® Agilex™ device.

    After that, CvP fails to recover even if you try to load the CvP bitstream from the same version.

    Resolution

    To work around this problem, you will need to power cycle the Intel® Agilex™ device.

     

    This problem is currently scheduled to be resolved in a future release of the Intel® Quartus® Prime Pro Edition Software.

    Related Products

    This article applies to 1 products

    Intel® Agilex™ 7 FPGAs and SoC FPGAs

    Disclaimer

    1

    All postings and use of the content on this site are subject to Intel.com Terms of Use.