Article ID: 000088096 Content Type: Product Information & Documentation Last Reviewed: 11/02/2021

When using the IOPLL clock switchover feature in Intel® Agilex™ devices, must inclk1 be in the same I/O bank as the IOPLL?

Environment

BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

Yes, when using the IOPLL clock switchover feature in Intel® Agilex™ devices, the secondary inclk1 input can only be sourced from dedicated clock inputs that are in the same I/O bank as the IOPLL. This restriction does not apply to inclk0 - only inclk1.

Resolution

The Intel® Agilex™ Clocking and PLL User Guide will be updated in a future release to include this information.