The OCT specifications for the HC210W devices are as follows:
For uncalibrated OCT, HC210W spec is similar to HC210.
=> /-30% for 3.3V, 2.5V & 1.8V for both commercial & industrial
=> /-36% for 1.5V for both commercial & industrial
For calibrated OCT, HC210W will need to add 5% more in the variation compared to HC210 due to more wirebond noise during calibration cycle.
=> /-10% for 3.3V, 2.5V & 1.8V commercial (from /-5% in HC210)
=> /-15% for 3.3V, 2.5V & 1.8V industrial (from /-10% in HC210)
=> /-13% for 1.5V commercial (from /-8% in HC210)
=> /-15% for 1.5V industrial (from /-10% in HC210)
Assumption is that the calibration is done at quiet VCCIO/GNDIO during programming.
Table 4-29 in the Chapter 4: DC & Switching Specifications & Operating Conditions in the HardCopy II Handbook will be updated soon to reflect this.