Description
The equivalent TimeQuest SDC constraints for QDRII SRAM legacy controller read capture in startix® II device are:
set_max_delay -0.2 -from * -to resync*
set_min_delay -1.6 -from * -to resync*
These constraints in Quartus® II software static Timing Analysis (TAN) are:
set_instance_assignment -name SETUP_RELATIONSHIP "– 0.2 ns" -from * – to resync*
set_instance_assignment -name HOLD_RELATIONSHIP "– 1.6 ns" -from * – to resync*