Article ID: 000082994 Content Type: Error Messages Last Reviewed: 10/03/2014

Internal Error: Sub-system: FIOMGR, File: /quartus/fitter/fiomgr/fiomgr_reserve_pin_op_impl.cpp, Line: 5002

Environment

  • Quartus® II Subscription Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description This internal error may be generated by the Quartus® II software when targeting MAX® 10 devices and setting the default IO standard to 3.0V or 3.3V.
    Resolution

    In the Quartus II software, choose a default IO standard of 2.5V or below from the Device and Pin Options, and then use the Assignment Editor or the Pin Planner to assign the desired 3.3V or 3.0V IO standard to the respective pins.

    This problem is scheduled to be fixed in a future release of the Quartus II software.