Due to a problem in Quartus Prime Version 16.1.0 Build169, you will see Error (12002): Port "clock" does not exist in macrofunction remote update and Error (12002): Port "reset" does not exist in macrofunction remote update when you instante a Altera Remote Update IP in your design and compile it.
This is because ports in **_inst.v file clock and reset are different from macro module **_altera_remote_update_161_umq4nxq, which are defined as clock_clk and reset_reset.
you can redefine the ports clock and reset in your design to clock_clk and reset_reset, then recompile. for example:
rsu_a10 u_rsu_a10 (
.clock_clk (inclk), // clock.clk
.reset_reset (reset), // reset.reset
.avl_csr_write (avl_csr_write), // avl_csr.write
.avl_csr_read (avl_csr_read), // .read
.avl_csr_writedata (avl_csr_writedata), // .writedata
.avl_csr_readdata (avl_csr_readdata), // .readdata
.avl_csr_readdatavalid (avl_csr_readdatavalid), // .readdatavalid
.avl_csr_waitrequest (avl_csr_waitrequest), // .waitrequest
.avl_csr_address (avl_csr_address) // .address
);