Article ID: 000082374 Content Type: Troubleshooting Last Reviewed: 01/30/2018

why you get Error (12002): Port "clock"/"reset" does not exist in macrofunction remote update IP when generate remote update IP?

Environment

    Intel® Quartus® Prime Pro Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

Due to a problem in Quartus Prime Version 16.1.0 Build169, you will see Error (12002): Port "clock" does not exist in macrofunction remote update   and Error (12002): Port "reset" does not exist in macrofunction remote update when you instante a Altera Remote Update IP in your design and compile it.

This is because ports in **_inst.v file clock and reset are different from  macro module **_altera_remote_update_161_umq4nxq, which are defined as clock_clk and reset_reset.




 

 

Resolution

you can redefine the ports clock and reset in your design to clock_clk and reset_reset, then  recompile. for example:

rsu_a10 u_rsu_a10 (

.clock_clk             (inclk),                 //   clock.clk

.reset_reset           (reset),                 //   reset.reset

.avl_csr_write         (avl_csr_write),         // avl_csr.write

.avl_csr_read          (avl_csr_read),          //        .read

.avl_csr_writedata     (avl_csr_writedata),     //        .writedata

.avl_csr_readdata      (avl_csr_readdata),      //        .readdata

.avl_csr_readdatavalid (avl_csr_readdatavalid), //        .readdatavalid

.avl_csr_waitrequest   (avl_csr_waitrequest),   //        .waitrequest

.avl_csr_address       (avl_csr_address)        //        .address

);

Related Products

This article applies to 1 products

Intel® Arria® 10 GT FPGA