Why do I get the following message in SOPC Builder: "### nios-build warning -2:Data memory exceeded, 4096 >= 1024. (Check boot_monitor_rom_contents.objdump.)"

Environment

BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description You will receive this message when you split your program and data memory into two separate memory blocks. However, your system will generate, compile, and work properly, and you can ignore this warning message.

This problem has been fixed in SOPC Builder versions 2.6x and higher.