Article ID: 000078327 Content Type: Troubleshooting Last Reviewed: 09/22/2011

Nios II IDE Command-Line Tools Hang on Windows

Environment

    Quartus® II Subscription Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT

Critical Issue

Description

On Windows systems, the Nios II IDE command-line tools are sometimes unable to locate the project workspace. When this happens, the tools might hang.

This issue potentially affects the following tools:

  • nios2-create-system-library
  • nios2-create-application-project
  • nios2-build-project
  • nios2-import-project
  • nios2-delete-project
Resolution

Explicitly supply the Nios II IDE command-line tools with a workspace location, by means of the -data command-line argument. The syntax of the -data argument is as follows:

-data <path to workspace>

The path to the workspace must be absolute, and must not contain whitespace. Aside from these restrictions, any valid file system path can be used for the workspace. The workspace shown in is the default workspace used by the Nios II IDE in version 9.0.

Providing a Workspace Location
nios2-create-project -data c:/altera/90/nios2eds/ bin/eclipse/nios2-ide-workspace-9.0 <other arguments>