Article ID: 000078161 Content Type: Troubleshooting Last Reviewed: 07/19/2017

Why does the Stratix 10 H-tile Transceiver Native PHY IP show incorrect magnitude range of pre-emphasis first pre-tap and first post-tap ?

Environment

  • Intel® Quartus® Prime Pro Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem with the Stratix® 10 H-tile Transceiver Native PHY IP in Quartus® Prime Pro Edition version 17.1 IR1, the magnitude range of pre-emphasis first pre-tap and first post-tap magnitude shown is incorrect.

    The correct magnitude range is 0 to 15 for pre-emphasis first pre-tap and 0 to 24 for pre-emphasis first post-tap.

    Resolution

    This problem has been fixed in Quartus Prime Pro Edition version 17.1 IR2  

    Related Products

    This article applies to 1 products

    Intel® Stratix® 10 FPGAs and SoC FPGAs

    Disclaimer

    1

    All postings and use of the content on this site are subject to Intel.com Terms of Use.