Article ID: 000077202 Content Type: Troubleshooting Last Reviewed: 02/13/2006

What is the correct boundary scan length for the EPF6024A device?

Environment

BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

The boundary scan length for the EPF6024A device is 666, as specified in the boundary-scan description language (BSDL) file.

The boundary scan length is incorrectly listed in the following sources:

  • In the 1999 Data Book, Table 9 of the FLEX 6000 Programmable Logic Device Family Data Sheet (page 442) specifies this value as 681, instead of 666.
  • The MAX PLUS II software version 9.3x shows this value as 675, instead of 666.

Related Products

This article applies to 1 products