Article ID: 000076594 Content Type: Troubleshooting Last Reviewed: 11/29/2017

Why do I see Board Selection Out of Range, when using the Stratix 10 Interlaken IP Core?

Environment

  • Intel® Quartus® Prime Pro Edition
  • Interlaken
  • Intel® FPGA IP 100G Interlaken IP-ILKN/100G
  • Intel® FPGA IP 50G Interlaken IP-ILKN/50G
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT

    Critical Issue

    Description

    When using the Intel® Stratix® 10 Interlaken IP Core (2nd Generation), you will see the error "Select Board (BOARD_SELECTION) 1 is out of range: No Development Kit", if the project device part is different to that on the dev it, and "Select Board" parameter is set to "Stratix 10 GX Signal Integrity Development Kit".

    The device fitted to the Stratix 10 GX Signal Integrity Development kit is the 1SG280HU2F50E2VGS1.

    Resolution

    To work around this problem, ensure your project device is set to that on the Stratix 10 GX Signal Integrity Kit(1SG280HU2F50E2VGS1), or set "Select Board" to "No Development Kit".

    This problem is scheduled to be fixed in a future release of the Intel Quartus® Prime Pro software.

    Related Products

    This article applies to 2 products

    Intel® Stratix® 10 FPGAs and SoC FPGAs
    Intel® Stratix® 10 GX FPGA

    Disclaimer