Article ID: 000076504 Content Type: Troubleshooting Last Reviewed: 10/09/2013

Why is the value of LED_LINK different than the value of the LINK_STATUS register in Triple Speed Ethernet (TSE) IP MegaCore function in Quartus II software version 13.0?

Environment

  • Quartus® II Subscription Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description  The LED_LINK signal can be different from the value of the  LINK_STATUS register in TSE IP MegaCore® function  in Quartus® II software version 13.0.

     

    This is due to the fact that the register will latch a value of 1'b0 to ensure the software knows that the link was lost.  Once read the LINK_STATUS register will update to the current link status.

     

    Please refer to the TSE user guide for the behavior description of LINK_STATUS.

    Resolution

     

    Related Products

    This article applies to 1 products

    Intel® Programmable Devices