Article ID: 000075107 Content Type: Troubleshooting Last Reviewed: 01/03/2023

In the table of Maximum Configuration Time Estimation for Intel® Stratix® 10 Devices, what do 170-230 MHz internal clock and 250 MHz internal clock represent?

Environment

    Intel® Quartus® Prime Pro Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

What do the 170-230 MHz internal clock and 250 MHz internal clocks that are stated in the Maximum Configuration Time Estimation for Intel®Stratix® 10 Devices table represent?

Resolution

The parameters 170-230 MHz and 250 MHz represent the clock for SDM operations.  The frequency depends on the setting of the configuration clock source in the Intel® Quartus® Prime Software.

Related Products

This article applies to 1 products

Intel® Stratix® 10 FPGAs and SoC FPGAs

1