Article ID: 000074444 Content Type: Troubleshooting Last Reviewed: 02/01/2023

Why does .jic file programming of EPCQ-A devices fail when multiple Intel® Cyclone® 10 LP devices are in the same JTAG chain?

Environment

  • Intel® Quartus® Prime Pro Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem in the Intel® Quartus® Prime Software version 18.1, the programming of EPCQ-A devices is executed incorrectly with JTAG Indirect Configuration (.jic) file.

    You will see the failure when there are more than three Intel® Cyclone® 10 LP devices in a single JTAG chain, where each is connected to an EPCQ-A device as configuration flash.

     

     

     

     

    Resolution

    This problem was fixed in a recent version of the Intel® Quartus® Prime Software.

     

     

    Related Products

    This article applies to 1 products

    Intel® Cyclone® 10 LP FPGA