Incorrect Programming File Compatibility for EPCS and EPCQ to EPCQA Devices in AN 822: Intel Configuration Device Migration Guideline

Environment

    Intel® Quartus® Prime Pro Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT

Critical Issue

Description

Issue 522006, 522405 : Chapter Software Migration Guidelines, section Programming File Compatibility, version 2018.01.11

The compatibility information in “Table 3: Programming File Compatibility for EPCS and EPCQ to EPCQA Devices” was preliminary and incorrect.

Resolution

Tthe following table shows the updated Programming File Compatibility for EPCS and EPCQ to EPCQA devices:

FPGA Device FamilyOriginal Configuration
Device
Configuration
Device Density
Programming Files supportedDisable EPCS/EPCQ ID check SettingCompatible
with EPCQA (1)(2)
Legacy FPGA devices
(Other devices than Cyclone® V, Arria® V or Stratix® V devices)
EPCS64Mb & below.pof/.jic/.rpd/.jam/.jbcAnyYes
.svfAnyYes (8)
128Mb.pof/.jic/.rpdAnyYes (3)
.svfAnyYes (8)
.jam/.jbcAnyNo (4)
EPCQAny.pof/.jic/.rpd/.jam/.jbcOn (5)Yes
.svfOn (5)Yes (8)
Cyclone® V, Arria® V or Stratix® V devicesEPCS64Mb & below.pof/.jic/.rpd/.jam/.jbcOn (6)Yes
.svfOn (6)Yes (8)
128Mb.pof/.jic/.rpdOn (6)Yes (3)
.svfOn (6)Yes (8)
.jam/.jbcAnyNo (4)
EPCQ (7)AnyAnyAnyNo

 

Notes:

Note 1 : This table assumes other compatibility considerations are satisfied

Note 2 : This table assumes the programming files do not contain any ASMI Parallel IP or Serial Flash Loader IP

Note 3 : In .rpd file, the binary data is the same between EPCS128 and EPCQ128A.  But due to different sector size, a proper erasing procedure is required when programming each device.

Note 4 : Due to different sector size, the .jam/.jbc file is different between EPCS and EPCQ.

Note 5 : Quartus II version 15.1 or later, automatic mode turns on this option automatically 

Note 6 : Other than Quartus II version 13.0 to 15.0, automatic mode turns on this option automatically

Note 7 :  EPCQ programming files are not compatible with EPCQ-A in AS x1 or AS x4 modes

Note 8 : Only supported for svf files generated for EPCS devices that program an EPCQ-A, but not the other way around