Intel® VROC for Windows*

The following information outlines the hot-plug features and functionality supported by Intel® VROC, including the Intel® VROC sub-products: Intel® VROC (VMD NVMe* RAID), Intel® VROC (SATA RAID) and Intel® VROC (Non-VMD NVMe* RAID). To learn about specific features supported by each Intel® VROC sub-product, refer to the following resources:

Intel® VROC Features Hot-plug is one of the features of the Intel® VROC family of products. To learn about other features of Intel® VROC, refer to the Intel® Virtual RAID on CPU (Intel® VROC) Technical Product Specification for Windows*.

The Intel® VROC family of products supports the ability to hot-plug (remove and replace) disk drives on properly configured and operational platforms whether or not the I/O is being processed. Hot-plug, also referred to as hot-swap, is a feature that allows disk drives (SATA or NVMe*) to be removed or inserted while the system is powered on and running under a Windows* operating system. As an example, hot-plug may be used to replace a failed drive that is in an externally accessible drive enclosure.

Managed Hot-Plug

Managed hot-plug support only applies to Intel® VROC (VMD NVMe* RAID) for both pass-thru drives and drives in a RAID volume. Intel® VROC (SATA RAID) currently does not contain support for managed hot-plug for SATA drives attached to the SATA, sSATA or tSATA controller. Managed hot-plug refers to the process of informing the system that a drive will be removed. To accomplish this, Intel® VROC has an option in the Intel® VROC Graphical User Interface (GUI) application that is used to provide this notification.

  1. Start the Intel® VROC GUI application (run as administrator).
  2. In the Devices pane, select the NVMe* drive to be removed.
  3. In the Disk Properties pane, look for Location Type and click on Remove Disk
  4. A message window will pop up asking to confirm the action. Click Yes to complete the action.

Surprise Hot-Plug

Intel® VROC supports surprise hot-plug on both pass-thru drives and drives in a RAID volume. Surprise hot-plug refers to removing a drive at any point and time. To be able to take advantage of this feature, the system and platform BIOS must have this feature enabled. Consult the platform design documentation for additional information.

Note Surprise and managed hot-plug are only supported in platforms that have hot-plug capable backplanes. Using the data cable and/or power cable plugging can result in unknown behavior.

How to Enable the BIOS for Hot-Plug

This series of instructions will guide users through the Intel BIOS configuration for enabling a RAID with a spare drive addition. This allows for configurations, such as a data volume using a file storage service, using multiple drives, or having backup drives ready in case a failure occurs, enabling Auto Rebuild to assist in the recovery.

Enabling Surprise Hot-Plug for Intel® VROC (VMD NVMe* RAID)

The following steps are an example of how to enable surprise hot-plug in the Intel Customer Reference Board (CRB) platform BIOS:

  1. Enter to the BIOS Setup menu.
  2. Navigate to the EDKII Menu, press Enter.
  3. Navigate to the Socket Configuration menu, press Enter.
  4. Navigate to the selection that reads PCIe Hot Plug. Press Enter to open the options menu, the user may toggle this setting between disabled and enabled. Select Enable, and press Enter to set selection.

This will enable the feature for all NVMe* drives that are associated with the system. This is a distinction from hot-plug as it works with PCH drives. Consult the user’s platform documentation because each BIOS is different, and the steps taken to enable this feature may be different.

Enabling Surprise Hot-Plug for Intel® VROC (SATA RAID)

The following steps are an example of how to enable surprise hot-plug in the Intel Customer Reference Board (CRB) platform BIOS:

  1. Enter to the BIOS Setup menu.
  2. Navigate to the EDKII Menu, press Enter.
  3. Navigate to the Platform Configuration menu, press Enter.
  4. Navigate to the PCH Configuration menu, press Enter.
  5. Navigate to the selection PCH SATA Configuration or PCH sSATA Configuration or PCH tSATA Configuration as appropriate, then press Enter.

Each port may be individually enabled for hot-plug. The user may turn this feature on for all or none of the ports as appropriate as the administrator. Consult the user’s platform documentation because each BIOS is different, and the steps taken to enable this feature may be different.

Pre-OS Hot-Plug Support

The Intel® VROC family of products supports the ability to perform drive hot-plugs in the Pre-OS environment when the drives are in a pass-thru configuration (not in a RAID volume). The Intel® VROC HII interface does not dynamically update, and the screen must be refreshed (by going up a menu level and coming back in) to see the hot-plug transition.

Intel® VROC does not currently support Pre-OS hot-plug on drives within a RAID volume.