How to Enable Volume Management Device (VMD) on Intel® Server M50FCP
Content Type: Install & Setup | Article ID: 000093944 | Last Reviewed: 02/27/2023
Does not know how to or which VMD to enable on Intel® Server M50FCP.
Follow below steps to enable VMD in the BIOS:
VMD to Front Drive Slots | VMD for M.2 NVMe* | |
M50FCP1UR204 (1U 4 x 2.5") | Direct HSBP VMD (CPU0, PE4) Direct HSBP VMD (CPU1, PE3) | PCIe M.2 VMD (CPU0 PCH) |
M50FCP1UR212 (1U 12 x 2.5") | Direct HSBP VMD (CPU0, PE3) Direct HSBP VMD (CPU0, PE4) Direct HSBP VMD (CPU1, PE4) | |
M50FCP2UR312 (2U 12 x 3.5") | Direct HSBP VMD (CPU0, PE4) | |
M50FCP2UR208 (2U 8 x 2.5") | Direct HSBP VMD (CPU0, PE4) Direct HSBP VMD (CPU1, PE3) | |
M50FCP2UR216 (2U 16 x 2.5") | Direct HSBP VMD (CPU0, PE3) Direct HSBP VMD (CPU0, PE4) Direct HSBP VMD (CPU1, PE3) Direct HSBP VMD (CPU1, PE4) | |
M50FCP2UR224 (2U 24 x 2.5") |
Direct HSBP VMD (CPU0, PE3) |
Press F10 and Y to save the settings.