Describes the steps for resolving the "P1 Therm Ctrl%" has gone over its upper threshold event reported by BMC (Baseboard Management Controller).
Unable to know what's the recommended troubleshooting steps for the P1 Therm Ctrl% Upper Critical / Non-Critical - going high event reported by BMC.
0100 - RID:0065 TS:04/14/2022 07:46:10 SN:P1 Therm Ctrl % ST:Temperature ED:Upper Non-critical - going high ET:Asserted EC:Non-Critical
0101 - RID:0066 TS:04/14/2022 07:46:10 SN:P1 Therm Ctrl % ST:Temperature ED:Upper Critical - going high ET:Asserted EC:Critical
Recommended steps for P1 Therm Ctrl% Upper Critical / Non-Critical - going high:
- Verify heat sink is properly attached and has thermal grease.
- If the system has a heat sink fan, ensure the fan is spinning.
- Check all system fans are operating properly.
- Check that the air used to cool the system is within limits (typically 35 °C).
Reference document: System Event Log (SEL) Troubleshooting Guide