Article ID: 000055834 Content Type: Error Messages Last Reviewed: 11/20/2023

How to Resolve the Error Code 84F2

Environment

Intel® Server Board S2600BP Family  

BUILT IN - ARTICLE INTRO SECOND COMPONENT
Summary

Steps to clear the CMOS (Complementary metal-oxide-semiconductor) in order to remove the error from the BIOS (Basic Input/Output System) screen

Description

The IPMI (Intelligent Platform Management Interface) on a node has failed, displaying the error code 84F2.

Resolution

The 84F2 code refers to the Baseboard management controller (BMC) failing to respond (See the System Firmware Progress (Formerly POST Error) – Next Steps section of the System Event Log Troubleshooting Guide).

In order to erase the error from the BIOS, proceed clearing the CMOS: 

  1. Plug out the compute module and remove the air duct.
  2. Move the jumper* from pins 1-2 to pins 2-3, momentarily. It is not necessary to leave the jumper in place while rebooting.
  3. Restore the jumper from pins 2-3 to the normal setting of pins 1-2.
  4. Install the air duct and plug in the compute module, and power up.
  5. Test.
NoteIf the BIOS Error Manager shows POST Error Codes 0012 (System RTC date/time not set) and/or 5220 (BIOS Settings reset to default settings), proceed as follows:
  1. Go to the Setup Main tab, and set the System Date and System Time to the correct current settings.
  2. Make any other changes that are required in Setup – for example, Boot Order.

 

Reference: The BIOS Default (J4B4) section  of the board Technical Product Specification.

If the issue persists, contact support with the Intel System Information Retrieval Utility extracted from your system. 

NoteIntel® Server's Integrated Baseboard Management Controller (BMC) can be accessed by standard, off-the-shelf terminal, open-sourced, or terminal emulator utilities. One example is the IPMIUtility that allows access to sensor status information and power control. Customers own the risk of using open-source utilities. Intel has no control on these utilities and cannot guarantee any fix with these utilities.

Related Products

This article applies to 2 products

Intel® Server System LWF1304LNETCENT