Management Subsystem Health, BMC FW Health errors in the logs
BMC firmware does not match with the latest version
Fans at full speed issue
When performing the standard Integrated Baseboard Management Controller (Integrated BMC) firmware update procedure, the update utility places the Integrated BMC into an update mode, allowing the firmware to load safely onto the flash device.
In the unlikely event the Integrated BMC firmware update process fails due to the Integrated BMC not being in the proper update state, the server board provides an Integrated BMC Force Update jumper, which forces the Integrated BMC into the proper update state.
The following procedure should be completed in the event the standard Integrated BMC firmware update process fails.
Note |
Integrated BMC functionality is disabled with the Force Integrated BMC Update jumper set to the enabled position. The server should never be run with the Integrated BMC Force Update jumper set in this position. This jumper setting should only be used when the standard firmware update process fails. This jumper should remain in the default/disabled position when the server is running normally. |
Information is taken from Intel® Server Board S2600CW Family TPS Revision 2.4 page 113