TA-901: Hard Disks May Not Initialize with Two Disks for Intel® Entry Storage System 4200-E
Content Type: Troubleshooting | Article ID: 000007654 | Last Reviewed: 07/12/2017
Issue description:
When installing only two hard disk drives in the Intel® Entry Storage System 4200-E:
Root cause:
Some systems may have been set for a four drive configuration during factory test. This causes the system to incorrectly detect a RAID failure with two drives installed.
Corrective action / resolution:
You may elect to install four drives into the storage system or proceed with the workaround.
To work around this issue with two drives installed:
This issue will be fixed in a future software release.
For additional information, see the Technical Advisory below.
Technical Advisory TA-901
File name: TA-901-1.pdf
Size: 29,232 KB
Date: March 2008
Note: PDF files require Adobe Acrobat Reader*